Difference between revisions of "LongAmp PCR NEB"
(→Thermocycling Conditions) |
(→Thermocycling Conditions) |
||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | == Reaction Setup | + | == Reaction Setup == |
{| class="wikitable" | {| class="wikitable" | ||
Line 27: | Line 27: | ||
| | | | ||
|} | |} | ||
− | |||
− | |||
'''Final Volume = 50µL''' | '''Final Volume = 50µL''' | ||
Line 77: | Line 75: | ||
− | To find annealing temperature, follow steps on the NEB Tm Calculator [http://tmcalculator.neb.com/#!/] | + | To find annealing temperature, follow steps on the NEB Tm Calculator, [http://tmcalculator.neb.com/#!/] which should yield a temperature 5°C below the Tm of the lower primer |
− | |||
− | == Modifications | + | == Modifications == |
• If template is GC rich, a longer initial denaturation of 2-4 minute is recommended | • If template is GC rich, a longer initial denaturation of 2-4 minute is recommended | ||
Line 110: | Line 107: | ||
| | | | ||
|} | |} | ||
+ | |||
+ | For more information, visit the NEB LongAmp Protocol [https://www.neb.com/protocols/2012/09/05/protocol-for-longamp-taq-2x-master-mix-m0287] |
Latest revision as of 20:09, 14 June 2016
Reaction Setup
REAGENT | VOLUME (µL) | FINAL CONC. |
---|---|---|
10 µM Forward Primer | 2 µL | 0.4 µM |
10 µM Reverse Primer | 2 µL | 0.4 µM |
Template DNA | Y (1ng) | 1 ng |
LongAmp Taq 2X Master Mix | 25 µL | 1X |
Nuclease-free Water | 21- Y |
Final Volume = 50µL
Notes:
• LongAmp Taq 2X Master Mix can be used to amplify templates of up to 30kb long.
• LongAmp Taq 2X Master Mix can be stored at -20°C, however, it is only stable for 15 freeze-thaw cycles. For more frequent use, NEB recommends storing it at 4°C.
• Remember to first dilute primers in nuclease-free water if starting with a higher concentration
• Do not exceed 50 µL final volume
Thermocycling Conditions
STEP | TEMPERATURE (°C) | TIME |
---|---|---|
Initial Denaturation | 94 | 1 min |
30 Cycles denature
anneal extend |
94
45-60 65 |
20 sec
40 sec 50 sec per kb |
Final Extension | 65 | 10 min |
Hold | 4-22 |
To find annealing temperature, follow steps on the NEB Tm Calculator, [1] which should yield a temperature 5°C below the Tm of the lower primer
Modifications
• If template is GC rich, a longer initial denaturation of 2-4 minute is recommended
• If annealing temperature is above 60°C, use two-step PCR protocol below
STEP | TEMPERATURE (°C) | TIME |
---|---|---|
Initial Denaturation | 94 | 1 min |
30 Cycles denature
anneal & extend |
94
60-65 |
20 sec
50 sec per kb |
Final Extension | 65 | 10 min |
Hold | 4-22 |