Difference between revisions of "Golden Gate Assembly Protocol"
From GcatWiki
Line 17: | Line 17: | ||
− | Turn on the thermal cycler machine. Put tube into machine. | + | Turn on the thermal cycler machine. Put tube into machine. For BsaI or BbsI GGA, program it for the following cycles: |
+ | |||
+ | :• 20 cycles | ||
+ | |||
+ | :• 37°C for 1 minute | ||
+ | |||
+ | :• 16°C for 1 minute | ||
+ | |||
+ | :• 22°C holding temperature | ||
+ | |||
+ | |||
+ | Turn on the thermal cycler machine. Put tube into machine. For BsmBI GGA, program it for the following cycles: | ||
:• 20 cycles | :• 20 cycles | ||
Line 29: | Line 40: | ||
:• 22°C holding temperature | :• 22°C holding temperature | ||
− | + | After GGA, the DNA is ready for transformation. You can increase the number of cycles to 30 if you want to increase yield. However, we have gotten good success with as few as 5 cycles. | |
Transformation of GGA | Transformation of GGA | ||
For each reaction done you will need an agar plate and 50µL of competent cells mixed with competent cell buffer. Mix the 50µL of cell mixture with the GGA product. Place the entire content of the tube on the plate, spread and incubate. | For each reaction done you will need an agar plate and 50µL of competent cells mixed with competent cell buffer. Mix the 50µL of cell mixture with the GGA product. Place the entire content of the tube on the plate, spread and incubate. |
Revision as of 19:22, 1 March 2016
Golden Gate Assembly Protocol GGA mixture contains:
- 1 µL (50 ng) Plasmid
- 1 µL promoter or other insert (1:1 molar ratio to Plasmid DNA)
- 1 µL 10X Promega Ligase Buffer
- 6 µL dH2O
- 0.5 µL Restriction enzyme (BsmBI-HF, BsaI-HF, or BbsI)
- 0.5 µL T4 DNA Ligase to the mixture
- 10 µL total volume
Turn on the thermal cycler machine. Put tube into machine. For BsaI or BbsI GGA, program it for the following cycles:
- • 20 cycles
- • 37°C for 1 minute
- • 16°C for 1 minute
- • 22°C holding temperature
Turn on the thermal cycler machine. Put tube into machine. For BsmBI GGA, program it for the following cycles:
- • 20 cycles
- • 55°C for 10 minutes
- • 37°C for 1 minute
- • 16°C for 1 minute
- • 22°C holding temperature
After GGA, the DNA is ready for transformation. You can increase the number of cycles to 30 if you want to increase yield. However, we have gotten good success with as few as 5 cycles.
Transformation of GGA For each reaction done you will need an agar plate and 50µL of competent cells mixed with competent cell buffer. Mix the 50µL of cell mixture with the GGA product. Place the entire content of the tube on the plate, spread and incubate.