# When the DNA extraction cools, vortex the tubes for 30 seconds and then set up a new 500 µL microfuge tube by adding the following:
 
# When the DNA extraction cools, vortex the tubes for 30 seconds and then set up a new 500 µL microfuge tube by adding the following:
  

Revision as of 14:00, 7 August 2012

  1. When the DNA extraction cools, vortex the tubes for 30 seconds and then set up a new 500 µL microfuge tube by adding the following:
Reagent Volume
extracted DNA 10.5 µL
2X Clear GoTaq Mix 12.5 µL
Forward Primer 1.0 µL
Reverse Primer 1.0 µL
Final Volume 25.0 µL


2. Run the thermocycler program called TAS2R38 with the heated lid enabled. PCR conditions:

  1. 5 minutes at 95˚C.
  2. 1 minute at 95˚C.
  3. 1 minute at 65˚C.
  4. 1 minute at 72˚C.
  5. repeat steps 2 - 5 29 more times.
  6. hold at room temperature.
  7. END

3. When the PCR is completed, store DNA frozen until you are ready to clean up the DNA in order to have your two alleles sequenced.